Ductwork cleaning in Berlin and Berlin-Brandenburg

We clean your ventilation.
Your operations keep running.

Inspection and cleaning based on VDI 6022. CCTV inspection up to 200 metres and, in many systems, cleaning without shutting down your production.

Technician in HI workwear and a respirator cleaning an open air handling unit with a spray lance
20+
years' experience
20,000+
systems cleaned
24h
until we reply
200m
CCTV inspection
Qualifications
Based on VDI 6022
Trained staff, cat. A and B
Independent laboratory testing
Can be done during operation
Since 2006
The blind spot

Everyone thinks about their health.Hardly anyone thinks about the air at work.

People invest a great deal in their own health. Yet the air that passes through their lungs eight hours a day comes from a system nobody has opened for years.

  • Regular exercise
  • A balanced diet
  • Filtered drinking water
  • Keeping an eye on sleep
Female technician on a stepladder cleaning a ceiling diffuser in an open-plan office with a brush and extraction hose
And then your employees spend eight hours breathing the air from exactly this system.

Under the German Workplace Ordinance (ArbStättV) and ASR A3.6, employers are obliged to provide air that is safe to breathe.

The decisive difference

Two ways through the same duct.

How the duct is accessed determines how much of your building has to be cut open in the end.

Conventional

Access by cutting open

13openings over 26 metres

Each opening has to be cut, cleaned and sealed again.

HI-Lüftungsservice

Access by robot

1opening for up to 200 metres

The robot travels the full run and cleans it completely.

Fewer leaks

Every additional opening in the duct is a point where air is permanently lost.

Lower additional costs

The operator has no panels, fitting or remedial work to pay for.

Work from an access platform

No scaffolding across the hall, and production does not have to be cleared.

The basis of our work

VDI 6022: what operators have to prove.

The guideline is a recognised code of practice. Its core principle: the air supplied must never be worse than the outdoor air.

Fixed intervals

Hygiene inspection every two years for systems with humidification, otherwise every three years. These are minimum intervals, not recommendations.

Measurable target value

After cleaning, the surface dust density must be below 10 g/m². If the value is exceeded, the system is cleaned again.

Trained staff

Inspection and cleaning are carried out only by staff trained to VDI 6022, categories A and B.

Documentation requirement

Every check and every inspection must be recorded in the logbook. Without a record, you have no defence if damage occurs.

Why this matters to you

The German Workplace Ordinance (ArbStättV) requires you to have ventilation and air-conditioning systems inspected in line with the state of the art. Missing records count as organisational negligence, and fines from the statutory accident insurance institutions (Berufsgenossenschaften) can reach €25,000.

Risk 1 · Hygiene

What grows in an uncleaned system.

Dust absorbs moisture, and spores and bacteria settle on the layer. Where water is involved, Legionella bacteria join them.

  • Humidifiers and condensate drip trays

    Standing water between 25 and 45 °C is the ideal breeding ground.

  • Ducts and air terminals

    Layers of dust absorb moisture, and mould and bacteria grow on them.

  • Filter stages

    Damp or overloaded filters stop protecting the system and become a source of contamination themselves.

Technician wearing a respirator taking a contact plate sample inside a ventilation duct by torchlight
6 to 9%

loss of productivity due to poor indoor air

130%

higher sickness absence at low ventilation rates

2 to 5 times

more polluted indoors than outdoors

Risk 2 · Operating costs

A clogged coil costs electricity every day.

Deposits increase the pressure drop. The unit has to work against its own dirt, around the clock.

Relative fan energy consumption
100
Before cleaning
50
After cleaning

Savings of 41 to 60 per cent are documented; the chart shows the midpoint of this range. Study: NADCA and University of Colorado, Energy and Buildings 2025.

1 mm

of deposits on the coil costs up to 10 per cent of heat transfer capacity

up to 50%

of total fan energy is consumed by clogged filters

up to 70%

of a commercial building's total energy goes on ventilation and air conditioning

In many systems, cleaning pays for itself through energy savings.

Inspection and cleaning

A robot that looks before it cleans

It all starts with a CCTV inspection. A remote-controlled robot with a 360-degree pan-and-tilt camera travels through your duct network and records the run. This shows us what is actually in the duct, and we also document air leakage, loose parts and damage to the insulation.

Cleaning is carried out section by section under negative pressure. An inflatable duct balloon seals off one section from the rest of the network, and the extraction unit draws the air out of it. Nothing reaches occupied rooms, and in many cases the rest of the system keeps running as normal. Where others cut an access panel every two metres, we need one access point every 50 to 100 metres.

The findings determine which tool we use: rotary brushes, air whip system, dry ice nozzle or coating nozzle. We usually clean air handling units wet, using high pressure and a collection system for the dirty water. Once the work is done, the camera runs through again and you receive the before-and-after evidence.

Inspection robot with camera and lights driving through a heavily soiled ventilation duct, operator at a laptop
Technical parameters
CCTV inspectionup to 200 mper access point
Duct access pointsevery 50 to 100 minstead of every 2 m
Cross-sectioncircular and rectangularup to walk-in size
Dry ice−78.5 °Cresidue-free
Attachments4 systemsbrush, air, ice, coating
Experiencesince 2006over 20 years
How we work

We fit in with your operations.

We seal off one section and clean it under negative pressure. The rest of the system keeps running as normal in the meantime.

During operation

Section by section, under negative pressure

0downtime of the whole system
Negative pressure
System runningSealed sectionSystem running

During operation

An inflatable duct balloon seals off the section and the extraction unit creates negative pressure. The rest of the system keeps running.

At night and at weekends

If your process needs air continuously, we come outside operating hours. Out-of-hours work at a surcharge.

During holidays and company shutdowns

The least disruptive option: we work while operations are at a standstill anyway, and you do not lose a single production hour.

Documentation

What you get at the end.

Every job is recorded. Before the work, during it and afterwards. This is your evidence for authorities, insurers and auditors.

Soiled ventilation duct before cleaning, with thick layers of dust on the walls, ceiling and floor
Before Duct as found
Duct cleaning robot with camera in a soiled ventilation shaft, with a technician at the control unit in the background
During Robot at work
Ventilation duct after cleaning, with bare, shiny galvanised sheet metal on all sides
After Cleaned section

CCTV inspection

Recording of the entire run, before and after cleaning

Cleaning report

Scope, method, date and the staff who carried out the work

Laboratory report

Contact plate samples and analysis by our partner laboratory

Inspection label

Visible on the system, with the date of the next inspection

HI-Lüftungsservice inspection label with fields for the month and year of the next inspection
Sectors

Where we clean.

Our focus is industrial production. That is where systems are largest, requirements are highest and downtime is most expensive.

Technician in a safety harness on an access platform cleaning a ventilation duct in an industrial hall

Industrial production

Large halls, high-level ducts, work from access platforms with full fall protection.

Cleanrooms and laboratories

Systems with stricter hygiene requirements and an obligation to document everything.

Hospitals and care facilities

Sensitive areas, concrete supply air ducts, coating and laboratory testing.

Technician on a stepladder cleaning a ceiling diffuser in an office with a brush and extraction hose

Offices and administration

Central ventilation and air-conditioning systems, air terminals, filter stages, airflow measurement.

Shipbuilding and yacht building

Onboard ventilation systems, including jobs outside Germany.

Residential buildings

Home ventilation systems (MVHR) in houses and blocks of flats.

Focus on Germany, with jobs across Europe including Austria and Switzerland.

Partners

Testing is carried out independently.

Whoever does the cleaning should not assess their own results. That is why independent laboratories carry out the hygiene testing.

BioStates

The first laboratory in Germany certified to VDI 6022

Contact plate samples, airborne microbial sampling and identification of more than 50 mould species. Accredited by DAkkS to DIN EN ISO/IEC 17025.

biostates.de

Hygiene-Institut-Mainfranken

Centre of expertise for hygiene and building biology

More than 45 years of experience, certified to DIN EN ISO 9001. Technical support and assessment by publicly recognised experts.

hygiene-institut-mainfranken.de

Separating the work from the testing is what really matters: you get a result that third parties will also accept.

Why HI-Lüftungsservice

Six reasons that make the difference

Working in industry, hospitals, cleanrooms, offices and shipbuilding since 2006.

Your operations can keep running

Section-by-section cleaning under negative pressure instead of shutting down the entire system. And if your process needs a constant air supply, we come at night, at the weekend or during your company shutdown.

Fewer cuts into the duct

One access point every 50 to 100 metres instead of an access panel every two metres. Every cut avoided is one leakage point fewer and saves you panels, fitting and remedial work.

Over 20 years of experience

Since 2006 in production halls, hospitals, cleanrooms, office buildings and shipbuilding. From commercial kitchens to onboard ventilation.

Evidence that stands up

CCTV inspection before and after the work, cleaning report, laboratory report and inspection label. All from a single source and in the format that auditors check.

Independent assessment

Independent partner laboratories carry out the microbiological testing. Whoever does the cleaning should not assess their own results.

Two methods, a single point of responsibility

Ventilation cleaning and dry ice cleaning from a single source. We tell you which method your system needs before the quotation, not after.

Initial assessment within 24 hours

Photos are enough to get started. Free of charge and without obligation.

Process

From enquiry to a clean system

The quickest route to a reliable quotation is a few photos of your system.

01

Photos or site visit

Send us photos of the air handling unit from the outside, an opened section of the unit, a view into the duct and the rating plate. Or we can come to you. Both are free of charge.

02

CCTV inspection

The robot records the current condition of the duct network. This shows the actual cleaning requirement, rather than a shot in the dark.

03

Your quotation

Tailored to your system, usually within 24 hours of your enquiry.

04

Scheduling and handover

During operation, at night, at the weekend or during your company shutdown. Afterwards: documentation, record and inspection label.

Water savings calculator

Calculate your
savings potential

Find out how much water and money you can save with ventilation cleaning

Average area per cleaning job (in m²)
Number of cleaning jobs per year
Your contacts

About HI-Lüftungsservice

Since 2006, working wherever there is ventilation.

Portrait of Jerome Thompson

Jerome Thompson

Management

Portrait of Heiko Ibert

Heiko Ibert

Management

Portrait of Gaetano De Michele

Gaetano De Michele

Management

Frequently asked questions

Ductwork cleaning in Berlin: frequently asked questions

Contact

Send us photos. We will take care of the rest.

We usually get back to you within 24 hours with an initial assessment and a quotation for your system.

  • Reply within 24 hours
    initial assessment of your system
  • Cleaning during operation
    without shutdown in many systems
  • CCTV inspection up to 200 metres
    findings before the quotation
  • Night, weekend, company shutdown
    out-of-hours work at a surcharge
  • In business since 2006
    head office in Würzburg, working across Europe
Request a quotation
A phone number or email is enough. We will discuss the rest with you personally.

Your data will be treated confidentially and will not be passed on to third parties.

Service area

Ductwork cleaning
in Berlin and Berlin-Brandenburg

Focus on Germany, with jobs across Europe including Austria and Switzerland.