Ductwork cleaning in Dortmund. Your operations keep running.
We inspect and clean ventilation systems and ductwork in Dortmund and Westphalia based on VDI 6022. CCTV inspection up to 200 metres and, in many systems, cleaning without shutting down your production.
Everyone thinks about their health.Hardly anyone thinks about the air at work.
People invest a great deal in their own health. Yet the air that passes through their lungs eight hours a day comes from a system nobody has opened for years.
Regular exercise
A balanced diet
Filtered drinking water
Keeping an eye on sleep
And then your employees spend eight hours breathing the air from exactly this system.
Under the German Workplace Ordinance (ArbStättV) and ASR A3.6, employers are obliged to provide air that is safe to breathe.
The decisive difference
Two ways through the same duct.
How the duct is accessed determines how much of your building has to be cut open in the end.
Without a robot
Access by cutting open
13openings over 26 metres, example
Each opening has to be cut, cleaned and sealed again.
HI-Lüftungsservice
Access by robot
1opening for up to 200 metres
The robot travels the run and cleans it section by section.
Fewer leaks
Every additional opening in the duct is a potential leakage point.
Lower additional costs
The operator largely saves on panels, fitting and remedial work.
Work from an access platform
No scaffolding across the hall, and production does not have to be cleared.
Services
Cleaning and testing for everything that carries air
From hygiene inspection and duct network cleaning to coating concrete ducts.
VDI 6022: what the guideline expects from operators.
The guideline is regarded as a recognised code of practice. Its core principle: the air supplied must never be worse than the outdoor air.
Fixed intervals
Hygiene inspection no later than every two years for systems with humidification, otherwise no later than every three years. The guideline states these intervals as maximum values.
Measurable target value
Cleanliness is measured gravimetrically in line with DIN EN 15780. Depending on the quality class, cleaning is required from 0.6 or 3 g/m², and after cleaning no more than 0.3 g/m² may remain.
Trained staff
Hygiene inspections require training to VDI 6022 category A. For cleaning, the guideline series provides its own qualifications, categories R and Q.
Complete documentation
Every check and every inspection must be recorded in the logbook. If damage occurs, the record is your most important evidence.
Why this matters to you
The German Workplace Ordinance (ArbStättV) requires you as an employer to maintain ventilation and air-conditioning systems and to have them checked regularly for proper functioning. ASR A3.6 requires defined inspection and maintenance intervals for this. Complete records allow you to demonstrate to authorities, insurers and auditors that you meet these obligations.
Risk 1 · Hygiene
What grows in an uncleaned system.
Dust absorbs moisture, and spores and bacteria settle on the layer. Where water is involved, Legionella bacteria join them.
Humidifiers and condensate drip trays
Standing water between 25 and 45 °C is the ideal breeding ground.
Ducts and air terminals
Layers of dust absorb moisture, and mould and bacteria grow on them.
Filter stages
Damp or overloaded filters stop protecting the system and become a source of contamination themselves.
6 to 9%
loss of productivity due to poor indoor air
1.5 times
the risk of short-term sick leave when the outdoor air supply is halved
2 to 5 times
more polluted indoors than outdoors
Risk 2 · Operating costs
A clogged coil costs electricity every day.
Deposits increase the pressure drop. The unit has to work against its own dirt, around the clock.
Relative fan energy consumption
100
Before cleaning
50
After cleaning
Field study of four systems: three showed 41 to 60 per cent less fan energy, and the chart shows the midpoint. University of Colorado for the US industry association NADCA, Energy and Buildings 2025. Not transferable to every system.
1 mm
of deposits on the coil costs up to 10 per cent of heat transfer capacity
up to 50%
of total fan energy is consumed by clogged filters
up to 70%
of a commercial building's total energy goes on ventilation and air conditioning
In heavily contaminated systems, cleaning can also pay off through energy savings.
Inspection and cleaning
A robot that sees the duct before it cleans it
It all starts with a CCTV inspection. A remote-controlled robot with a 360-degree pan-and-tilt camera travels through your duct network and records the run. This shows us what is actually in the duct, and we also document air leakage, loose parts and damage to the insulation.
Cleaning is carried out section by section under negative pressure. An inflatable duct balloon seals off one section from the rest of the network, and the extraction unit draws the air out of it. Nothing reaches occupied rooms, and in many cases the rest of the system keeps running as normal. Instead of many additional access panels, we usually need one access point every 50 to 100 metres.
The findings determine which tool we use: rotary brushes, air whip system, dry ice nozzle or coating nozzle. We usually clean air handling units wet, using high pressure and a collection system for the dirty water. Once the work is done, the camera runs through again and you receive the before-and-after evidence.
Technical parameters
CCTV inspectionup to 200 mper access point
Duct access pointsevery 50 to 100 minstead of many panels
Cross-sectioncircular and rectangularup to walk-in size
Dry ice−78.5 °Cresidue-free
Attachments4 systemsbrush, air, ice, coating
Experiencesince 2006over 20 years
How we work
We fit in with your operations.
We seal off one section and clean it under negative pressure. In many systems, the rest keeps running as normal in the meantime.
During operation
Section by section, under negative pressure
0downtime of the whole system in many cases
Negative pressure
System runningSealed sectionSystem running
During operation
An inflatable duct balloon seals off the section and the extraction unit creates negative pressure. The rest of the system keeps running.
At night and at weekends
If your process needs air continuously, we come outside operating hours. Out-of-hours work at a surcharge.
During holidays and company shutdowns
The least disruptive option: we work while operations are at a standstill anyway, and you do not lose a single production hour.
Documentation
What you get at the end.
Every job is recorded. Before the work, during it and afterwards. This is your evidence for authorities, insurers and auditors.
Before Duct as found
During Robot at work
After Cleaned section
CCTV inspection
Recording of the entire run, before and after cleaning
Cleaning report
Scope, method, date and the staff who carried out the work
Laboratory report
Contact plate samples and analysis by our partner laboratory
Inspection label
Visible on the system, with the date of the next inspection
Sectors
Where we clean: industry, hospitals, laboratories and offices.
Our focus is industrial production. That is where systems are largest, requirements are highest and downtime is most expensive.
Industrial production
Large halls, high-level ducts, work from access platforms with full fall protection.
Cleanrooms and laboratories
Systems with stricter hygiene requirements and an obligation to document everything.
Hospitals and care facilities
Sensitive areas, concrete supply air ducts, coating and laboratory testing.
Offices and administration
Central ventilation and air-conditioning systems, air terminals, filter stages, airflow measurement.
Shipbuilding and yacht building
Onboard ventilation systems, including jobs outside Germany.
Residential buildings
Home ventilation systems (MVHR) in houses and blocks of flats.
Focus on Germany, with jobs across Europe including Austria and Switzerland.
Partners
Testing is carried out independently.
Whoever does the cleaning should not analyse their own samples. That is why independent laboratories carry out the microbiological analysis.
BioStates
Laboratory for the hygiene of ventilation systems
Contact plate samples, airborne microbial sampling and identification of more than 50 mould species and genera. Accredited by DAkkS to DIN EN ISO/IEC 17025.
Separating the work from the laboratory analysis is what really matters: you receive independent findings that you can present to third parties.
HI-Industrieservice
Dry ice, laser and LED from a single source
Alongside ventilation cleaning, our HI-Industrieservice division cleans machines, systems and components with dry ice, removes rust and coatings by laser and marks factory floors with light.
Dry ice cleaning without water, chemicals or dismantling
Laser cleaning for rust, paint and coatings
LED floor marking for walkways, zones and hazard areas
Working in industry, hospitals, cleanrooms, offices and shipbuilding since 2006.
Your operations can keep running
Section-by-section cleaning under negative pressure instead of shutting down the entire system. And if your process needs a constant air supply, we come at night, at the weekend or during your company shutdown.
Fewer cuts into the duct
Usually one access point every 50 to 100 metres instead of many additional access panels. Every cut avoided saves you panels, fitting, remedial work and a potential leakage point.
Over 20 years of experience
Since 2006 in production halls, hospitals, cleanrooms, office buildings and shipbuilding. From commercial kitchens to onboard ventilation.
Evidence that stands up
CCTV inspection before and after the work, cleaning report and inspection label, with a laboratory report on request. All from a single source and in the format that auditors check.
Independent laboratory analysis
Independent partner laboratories analyse the microbiological samples. Whoever does the cleaning should not analyse their own samples.
Two methods, a single point of responsibility
Ventilation cleaning and dry ice cleaning from a single source. We tell you which method your system needs before the quotation, not after.
Initial assessment usually within 24 hours
Photos are enough to get started. Free of charge and without obligation.
The quickest route to a reliable quotation is a few photos of your system.
01
Photos or site visit
Send us photos of the air handling unit from the outside, an opened section of the unit, a view into the duct and the rating plate. Or we can come to you. Both are free of charge.
02
CCTV inspection
The robot records the current condition of the duct network. This shows the actual cleaning requirement, rather than a shot in the dark.
03
Your quotation
Tailored to your system. If photos are enough for an assessment, it is quick. If a CCTV inspection is needed, we agree the date with you in advance.
04
Scheduling and handover
During operation, at night, at the weekend or during your company shutdown. Afterwards: documentation, record and inspection label.
Water savings calculator
Calculate your savings potential
Find out how much water and money you can save with ventilation cleaning
Average area per cleaning job (in m²)
Number of cleaning jobs per year
Your contacts
About HI-Lüftungsservice
Since 2006, working wherever there is ventilation.
Ductwork cleaning in Dortmund: frequently asked questions
The key guideline for ventilation and air-conditioning systems is VDI 6022. For the cleaning itself, we work on the basis of VDI 6022 Part 8, published in 2024, which deals specifically with cleaning ventilation systems and ductwork. For kitchen extract systems, VDI 2052 applies. In addition, the German Workplace Ordinance (ArbStättV) and ASR A3.6 require employers to provide air that is safe to breathe.
Often not. We seal off individual duct sections with an inflatable duct balloon and create negative pressure there. The rest of the system keeps running. If your process needs a constant air supply, we work at night, at the weekend or during your company shutdown. Out-of-hours work is charged at a surcharge.
Because we travel through the duct run with a robot instead of cutting additional openings into the duct. One access point every 50 to 100 metres is usually enough. This saves you the panels and their fitting, and there are fewer potential leakage points in the duct.
An independent testing laboratory. We work with BioStates in Baden-Baden and the Hygiene-Institut-Mainfranken. Separating the work from the laboratory analysis is deliberate: you receive findings that do not come from us and that you can present to third parties.
That depends on the size of the system, the level of contamination and accessibility, so there is no general answer. That is why we always start with a survey of the system. Send us a few photos and we can give you a realistic estimate of the work involved.
Yes. Our focus is on Germany, but our work takes us across Europe, including Austria and Switzerland. In shipbuilding and yacht building in particular, we regularly work abroad.
Our head office is in Würzburg, with further locations in Oberboihingen and Stuttgart. We focus on Germany and work across Europe, including Austria and Switzerland.
Contact
Send us photos. We will take care of the rest.
We usually get back to you within 24 hours with an initial assessment of your system.
Reply within 24 hours usually, with an initial assessment
Cleaning during operation without shutdown in many systems
CCTV inspection up to 200 metres findings before the quotation
Night, weekend, company shutdown out-of-hours work at a surcharge
In business since 2006 head office in Würzburg, working across Europe
Request a quotation
Your name, phone number and email are enough. We will discuss the rest with you personally.
Service area
Ductwork cleaning in Dortmund and Westphalia
Focus on Germany, with jobs across Europe including Austria and Switzerland.